CCE
view XML

CCE-95783-7

Platform: cpe:/o:ubuntu:ubuntu_linux:20.04Date: (C)2024-02-12   (M)2024-02-12



Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events.The Ubuntu operating system must synchronize internal information system clocks to the authoritative time source when the time difference is greater than one second. Fixtext: Edit the "/etc/chrony/chrony.conf" file and add: makestep 1 -1 Restart the chrony service: $ sudo systemctl restart chrony.service


Parameter:

[Yes/No]


Technical Mechanism:

Edit the "/etc/chrony/chrony.conf" file and add: makestep 1 -1 Restart the chrony service: $ sudo systemctl restart chrony.service

CCSS Severity:CCSS Metrics:
CCSS Score : 5.4Attack Vector: NETWORK
Exploit Score: 2.8Attack Complexity: LOW
Impact Score: 2.5Privileges Required: LOW
Severity: MEDIUMUser Interaction: NONE
Vector: AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:NScope: UNCHANGED
 Confidentiality: LOW
 Integrity: LOW
 Availability: NONE
  

References:
Resource IdReference
SCAP Repo OVAL Definitionoval:org.secpod.oval:def:97836


OVAL    1
oval:org.secpod.oval:def:97836
XCCDF    1
xccdf_org.secpod_benchmark_general_Ubuntu_20.04

© SecPod Technologies