A Stack-based Buffer Overflow issue was discovered in SpiderControl SCADA MicroBrowser Versions 1.6.30.144 and prior. Opening a maliciously crafted html file may cause a stack overflow.

An Improper Restriction Of Operations Within The Bounds Of A Memory Buffer issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. Researchers have identified multiple vulnerabilities that allow invalid locations to be referenced for the memory buffer, which may allow an attacker to execute arbitrary code or cause the system to crash.

A Use of Hard-Coded Credentials issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded credentials, which could allow for unauthorized local low-privileged access to the device.

IBM Security Guardium 9.0, 9.1, and 9.5 supports interaction between multiple actors and allows those actors to negotiate which algorithm should be used as a protection mechanism such as encryption or authentication, but it does not select the strongest algorithm that is available to both parties. IBM X-Force ID: 124746.

A SQL Injection issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. By submitting a specially crafted parameter, it is possible to inject arbitrary SQL statements that could allow an attacker to obtain sensitive information.

An Incorrect Privilege Assignment issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. A built-in user account has been granted a sensitive privilege that may allow a user to elevate to administrative privileges.

The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmwa ...

An Incorrect Permission Assignment for Critical Resource issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. Multiple files and folders with ACLs that affect other users are allowed to be modified by non-administrator accounts.

Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitiga ...

Abbott Laboratories Accent and Anthem pacemakers manufactured prior to Aug 28, 2017 transmit unencrypted patient information via RF communications to programmers and home monitoring units. Additionally, the Accent and Anthem pacemakers store the optional patient information without encryption. CVSS v3 base score: 3.1, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N. Abbott has developed a ...