[Forgot Password]
Login  Register Subscribe

30481

 
 

423868

 
 

256288

 
 

909

 
 

199146

 
 

282

Paid content will be excluded from the download.


Download | Alert*
CVE
view JSON

CVE-2018-0026Date: (C)2018-07-12   (M)2023-12-22


After Junos OS device reboot or upgrade, the stateless firewall filter configuration may not take effect. This issue can be verified by running the command: user@re0> show interfaces extensive | match filters" CAM destination filters: 0, CAM source filters: 0 Note: when the issue occurs, it does not show the applied firewall filter. The correct output should show the applied firewall filter, for example: user@re0> show interfaces extensive | match filters" CAM destination filters: 0, CAM source filters: 0 Input Filters: FIREWAL_FILTER_NAME- This issue affects firewall filters for every address family. Affected releases are Juniper Networks Junos OS: 15.1R4, 15.1R5, 15.1R6 and SRs based on these MRs. 15.1X8 versions prior to 15.1X8.3.

CVSS Score and Metrics +CVSS Score and Metrics -

CVSS V3 Severity:CVSS V2 Severity:
CVSS Score : 7.5CVSS Score : 5.0
Exploit Score: 3.9Exploit Score: 10.0
Impact Score: 3.6Impact Score: 2.9
 
CVSS V3 Metrics:CVSS V2 Metrics:
Attack Vector: NETWORKAccess Vector: NETWORK
Attack Complexity: LOWAccess Complexity: LOW
Privileges Required: NONEAuthentication: NONE
User Interaction: NONEConfidentiality: NONE
Scope: UNCHANGEDIntegrity: PARTIAL
Confidentiality: NONEAvailability: NONE
Integrity: HIGH 
Availability: NONE 
  
Reference:
SECTRACK-1041315
BID-104720
https://kb.juniper.net/JSA10859

CPE    3
cpe:/o:juniper:junos:15.1:r4
cpe:/o:juniper:junos:15.1:r5
cpe:/o:juniper:junos:15.1:r6

© SecPod Technologies