CVE-2020-12523 | Date: (C)2020-12-18 (M)2023-12-22 |
On Phoenix Contact mGuard Devices versions before 8.8.3 LAN ports get functional after reboot even if they are disabled in the device configuration. For mGuard devices with integrated switch on the LAN side, single switch ports can be disabled by device configuration. After a reboot these ports get functional independent from their configuration setting: Missing Initialization of Resource
CVSS Score and Metrics +CVSS Score and Metrics -CVSS V3 Severity: | CVSS V2 Severity: |
CVSS Score : 9.1 | CVSS Score : 6.4 |
Exploit Score: 3.9 | Exploit Score: 10.0 |
Impact Score: 5.2 | Impact Score: 4.9 |
|
CVSS V3 Metrics: | CVSS V2 Metrics: |
Attack Vector: NETWORK | Access Vector: NETWORK |
Attack Complexity: LOW | Access Complexity: LOW |
Privileges Required: NONE | Authentication: NONE |
User Interaction: NONE | Confidentiality: PARTIAL |
Scope: UNCHANGED | Integrity: NONE |
Confidentiality: HIGH | Availability: PARTIAL |
Integrity: NONE | |
Availability: HIGH | |
| |