[Forgot Password]
Login  Register Subscribe

30480

 
 

423868

 
 

253164

 
 

909

 
 

197077

 
 

282

 
 
Paid content will be excluded from the download.

Filter
Matches : 251453 Download | Alert*

A kernel pool overflow in the driver hitmanpro37.sys in Sophos SurfRight HitmanPro before 3.7.20 Build 286 (included in the HitmanPro.Alert solution and Sophos Clean) allows local users to escalate privileges via a malformed IOCTL call.

An issue was discovered in icoutils 0.31.1. A buffer overflow was observed in the "decode_ne_resource_id" function in the "restable.c" source file. This is happening because the "len" parameter for memcpy is not checked for size and thus becomes a negative integer in the process, resulting in a failed memcpy. This affects wrestool.

An issue was discovered in icoutils 0.31.1. A buffer overflow was observed in the "extract_icons" function in the "extract.c" source file. This issue can be triggered by processing a corrupted ico file and will result in an icotool crash.

An issue was discovered in icoutils 0.31.1. An out-of-bounds read leading to a buffer overflow was observed in the "simple_vec" function in the "extract.c" source file. This affects icotool.

Subrion CMS 4.0.5.10 has SQL injection in admin/database/ via the query parameter.

In Wireshark 2.2.4 and earlier, a crafted or malformed STANAG 4607 capture file will cause an infinite loop and memory exhaustion. If the packet size field in a packet header is null, the offset to read from will not advance, causing continuous attempts to read the same zero length packet. This will quickly exhaust all system memory.

Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N ...

An Improper Access Control issue was discovered in LCDS - Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA. The following versions are affected: Versions 4.1 and prior versions released before January 20, 2017. An Improper Access Control vulnerability has been identified, which may allow an authenticated user to modify application files to escalate privileges.

An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The w ...

An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot.


Pages:      Start    14943    14944    14945    14946    14947    14948    14949    14950    14951    14952    14953    14954    14955    14956    ..   25145

© SecPod Technologies