CVE-2021-33535 | Date: (C)2021-06-28 (M)2023-12-22 |
In Weidmueller Industrial WLAN devices in multiple versions an exploitable format string vulnerability exists in the iw_console conio_writestr functionality. A specially crafted time server entry can cause an overflow of the time server buffer, resulting in remote code execution. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.
CVSS Score and Metrics +CVSS Score and Metrics -CVSS V3 Severity: | CVSS V2 Severity: |
CVSS Score : 8.8 | CVSS Score : 6.5 |
Exploit Score: 2.8 | Exploit Score: 8.0 |
Impact Score: 5.9 | Impact Score: 6.4 |
|
CVSS V3 Metrics: | CVSS V2 Metrics: |
Attack Vector: NETWORK | Access Vector: NETWORK |
Attack Complexity: LOW | Access Complexity: LOW |
Privileges Required: LOW | Authentication: SINGLE |
User Interaction: NONE | Confidentiality: PARTIAL |
Scope: UNCHANGED | Integrity: PARTIAL |
Confidentiality: HIGH | Availability: PARTIAL |
Integrity: HIGH | |
Availability: HIGH | |
| |