[Forgot Password]
Login  Register Subscribe

30479

 
 

423868

 
 

250039

 
 

909

 
 

195882

 
 

282

Paid content will be excluded from the download.


Download | Alert*
CVE
view JSON

CVE-2021-27386Date: (C)2021-05-13   (M)2023-12-22


A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4" - 22" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.

CVSS Score and Metrics +CVSS Score and Metrics -

CVSS V3 Severity:CVSS V2 Severity:
CVSS Score : 7.5CVSS Score : 5.0
Exploit Score: 3.9Exploit Score: 10.0
Impact Score: 3.6Impact Score: 2.9
 
CVSS V3 Metrics:CVSS V2 Metrics:
Attack Vector: NETWORKAccess Vector: NETWORK
Attack Complexity: LOWAccess Complexity: LOW
Privileges Required: NONEAuthentication: NONE
User Interaction: NONEConfidentiality: NONE
Scope: UNCHANGEDIntegrity: NONE
Confidentiality: NONEAvailability: PARTIAL
Integrity: NONE 
Availability: HIGH 
  
Reference:
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12

CWE    1
CWE-401

© SecPod Technologies