CVE-2020-12038Date: (C)2020-05-20   (M)2023-12-22


Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions.

CVSS Score and Metrics +CVSS Score and Metrics -

CVSS V3 Severity:CVSS V2 Severity:
CVSS Score : 5.5CVSS Score : 4.3
Exploit Score: 1.8Exploit Score: 8.6
Impact Score: 3.6Impact Score: 2.9
 
CVSS V3 Metrics:CVSS V2 Metrics:
Attack Vector: LOCALAccess Vector: NETWORK
Attack Complexity: LOWAccess Complexity: MEDIUM
Privileges Required: NONEAuthentication: NONE
User Interaction: REQUIREDConfidentiality: NONE
Scope: UNCHANGEDIntegrity: NONE
Confidentiality: NONEAvailability: PARTIAL
Integrity: NONE 
Availability: HIGH 
  
Reference:
https://www.us-cert.gov/ics/advisories/icsa-20-140-01

CWE    1
CWE-787

© SecPod Technologies