[Forgot Password]
Login  Register Subscribe

30479

 
 

423868

 
 

249461

 
 

909

 
 

195508

 
 

282

Paid content will be excluded from the download.


Download | Alert*
CVE
view JSON

CVE-2019-12182Date: (C)2020-03-16   (M)2023-12-22


Directory Traversal in Safescan Timemoto and TA-8000 series version 1.0 allows unauthenticated remote attackers to execute code via the administrative API.

CVSS Score and Metrics +CVSS Score and Metrics -

CVSS V3 Severity:CVSS V2 Severity:
CVSS Score : 9.8CVSS Score : 7.5
Exploit Score: 3.9Exploit Score: 10.0
Impact Score: 5.9Impact Score: 6.4
 
CVSS V3 Metrics:CVSS V2 Metrics:
Attack Vector: NETWORKAccess Vector: NETWORK
Attack Complexity: LOWAccess Complexity: LOW
Privileges Required: NONEAuthentication: NONE
User Interaction: NONEConfidentiality: PARTIAL
Scope: UNCHANGEDIntegrity: PARTIAL
Confidentiality: HIGHAvailability: PARTIAL
Integrity: HIGH 
Availability: HIGH 
  
Reference:
https://github.com/ProCheckUp/SafeScan
https://procheckup.com/blogs/posts/2020/february/remote-code-execution-on-biometric-iot-devices/
https://safescan.com/
https://support.timemoto.com/en/s/safescan-time-clock-systems/a/firmware-update-7-dot-03-dot-100-ta8000-14

CWE    1
CWE-22

© SecPod Technologies