[Forgot Password]
Login  Register Subscribe

30479

 
 

423868

 
 

249622

 
 

909

 
 

195549

 
 

282

Paid content will be excluded from the download.


Download | Alert*
CVE
view JSON

CVE-2017-5569Date: (C)2017-01-31   (M)2023-12-22


An issue was discovered in eClinicalWorks Patient Portal 7.0 build 13. This is a blind SQL injection within the template.jsp, which can be exploited without the need of authentication and via an HTTP POST request, and which can be used to dump database data out to a malicious server, using an out-of-band technique such as select_loadfile().

CVSS Score and Metrics +CVSS Score and Metrics -

CVSS V3 Severity:CVSS V2 Severity:
CVSS Score : 9.8CVSS Score : 7.5
Exploit Score: 3.9Exploit Score: 10.0
Impact Score: 5.9Impact Score: 6.4
 
CVSS V3 Metrics:CVSS V2 Metrics:
Attack Vector: NETWORKAccess Vector: NETWORK
Attack Complexity: LOWAccess Complexity: LOW
Privileges Required: NONEAuthentication: NONE
User Interaction: NONEConfidentiality: PARTIAL
Scope: UNCHANGEDIntegrity: PARTIAL
Confidentiality: HIGHAvailability: PARTIAL
Integrity: HIGH 
Availability: HIGH 
  
Reference:
BID-95741
https://gist.github.com/malerisch/d32d127a002ac1f10bce39333ca9a4dc

CWE    1
CWE-89