CVE-2017-12786 | Date: (C)2017-08-24 (M)2023-12-22 |
Network interfaces of the cliengine and noviengine services, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, can be inadvertently exposed if an operator attempts to modify ACLs, because of a bug when ACL modifications are applied. This could be leveraged by remote, unauthenticated attackers to gain resultant privileged (root) code execution on the switch, because there is a stack-based buffer overflow during unserialization of packet data.
CVSS Score and Metrics +CVSS Score and Metrics -CVSS V3 Severity: | CVSS V2 Severity: |
CVSS Score : 9.8 | CVSS Score : 10.0 |
Exploit Score: 3.9 | Exploit Score: 10.0 |
Impact Score: 5.9 | Impact Score: 10.0 |
|
CVSS V3 Metrics: | CVSS V2 Metrics: |
Attack Vector: NETWORK | Access Vector: NETWORK |
Attack Complexity: LOW | Access Complexity: LOW |
Privileges Required: NONE | Authentication: NONE |
User Interaction: NONE | Confidentiality: COMPLETE |
Scope: UNCHANGED | Integrity: COMPLETE |
Confidentiality: HIGH | Availability: COMPLETE |
Integrity: HIGH | |
Availability: HIGH | |
| |