[Forgot Password]
Login  Register Subscribe

30479

 
 

423868

 
 

248678

 
 

909

 
 

195426

 
 

282

Paid content will be excluded from the download.


Download | Alert*
CVE
view JSON

CVE-2013-5021Date: (C)2013-08-14   (M)2023-12-22


Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.

CVSS Score and Metrics +CVSS Score and Metrics -

CVSS V2 Severity:
CVSS Score : 9.3
Exploit Score: 8.6
Impact Score: 10.0
 
CVSS V2 Metrics:
Access Vector: NETWORK
Access Complexity: MEDIUM
Authentication: NONE
Confidentiality: COMPLETE
Integrity: COMPLETE
Availability: COMPLETE
  
Reference:
http://digital.ni.com/public.nsf/allkb/04B876608790082C86257BD1000CC950?OpenDocument
http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument
http://www05.abb.com/global/scot/scot203.nsf/veritydisplay/5975a8a86c82eec2c125798e00551522/%24file/SECURITY_BULLETIN_-_ABBVU-PACT-3BSE072617_DataManager_Vulnerability.pdf
http://zerodayinitiative.com/advisories/ZDI-13-120/

CPE    2
cpe:/a:abb:datamanager:1.0.0
cpe:/a:abb:datamanager:6.3.6
CWE    1
CWE-22

© SecPod Technologies