CVE-2012-4359 | Date: (C)2012-08-19 (M)2023-12-22 |
Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 do not validate the return value of the realloc function, which allows remote attackers to cause a denial of service (invalid 0x00 write operation and daemon crash) or possibly have unspecified other impact via a port-46824 TCP packet with a crafted negative integer after the opcode. NOTE: this vulnerability exists because of an incomplete fix for CVE-2012-4358.
CVSS Score and Metrics +CVSS Score and Metrics -CVSS V2 Severity: |
CVSS Score : 9.3 |
Exploit Score: 8.6 |
Impact Score: 10.0 |
|
CVSS V2 Metrics: |
Access Vector: NETWORK |
Access Complexity: MEDIUM |
Authentication: NONE |
Confidentiality: COMPLETE |
Integrity: COMPLETE |
Availability: COMPLETE |
| |