CVE-2018-0298 | Date: (C)2018-06-21 (M)2023-12-22 |
A vulnerability in the web UI of Cisco FXOS and Cisco UCS Fabric Interconnect Software could allow an unauthenticated, remote attacker to cause a buffer overflow on an affected system. The vulnerability is due to incorrect input validation in the web UI. An attacker could exploit this vulnerability by sending a malicious HTTP or HTTPS packet directed to the physical management interface of an affected system. A successful exploit could allow the attacker to cause the process to crash and possibly reload the device, resulting in a denial of service (DoS) condition on the affected system. This vulnerability affects Firepower 4100 Series Next-Generation Firewall, Firepower 9300 Security Appliance, UCS 6200 Series Fabric Interconnects, UCS 6300 Series Fabric Interconnects. Cisco Bug IDs: CSCvb61398, CSCvb86799.
CVSS Score and Metrics +CVSS Score and Metrics -CVSS V3 Severity: | CVSS V2 Severity: |
CVSS Score : 7.5 | CVSS Score : 7.8 |
Exploit Score: 3.9 | Exploit Score: 10.0 |
Impact Score: 3.6 | Impact Score: 6.9 |
|
CVSS V3 Metrics: | CVSS V2 Metrics: |
Attack Vector: NETWORK | Access Vector: NETWORK |
Attack Complexity: LOW | Access Complexity: LOW |
Privileges Required: NONE | Authentication: NONE |
User Interaction: NONE | Confidentiality: NONE |
Scope: UNCHANGED | Integrity: NONE |
Confidentiality: NONE | Availability: COMPLETE |
Integrity: NONE | |
Availability: HIGH | |
| |