cpe:/a:siemens:sinumerik_828d:4.8:- cpe:/a:siemens:sinumerik_828d:4.8:sp1 cpe:/a:siemens:sinumerik_828d:4.8:sp2 cpe:/a:siemens:sinumerik_828d:4.8:sp3 cpe:/a:siemens:sinumerik_828d:4.8:sp4 cpe:/a:siemens:sinumerik_840d_sl cpe:/o:siemens:_simatic_s7-300_cpu_314_firmware cpe:/o:siemens:dk_standard_ethernet_controller_firmware cpe:/o:siemens:ek-ertec_200_firmware cpe:/o:siemens:ek-ertec_200p_firmware cpe:/o:siemens:simatic_et_200al_firmware cpe:/o:siemens:simatic_et_200ecopn_firmware cpe:/o:siemens:simatic_et_200m_firmware cpe:/o:siemens:simatic_et_200mp_im_155-5_pn_hf_firmware cpe:/o:siemens:simatic_et_200mp_im_155-5_pn_st_firmware cpe:/o:siemens:simatic_et_200pro_firmware cpe:/o:siemens:simatic_et_200s_firmware cpe:/o:siemens:simatic_et_200sp_im_155-6_pn_ba_firmware cpe:/o:siemens:simatic_et_200sp_im_155-6_pn_ha_firmware cpe:/o:siemens:simatic_et_200sp_im_155-6_pn_hs_firmware cpe:/o:siemens:simatic_et_200sp_im_155-6_pn_st_firmware cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_15%22_firmware cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_7%22_firmware cpe:/o:siemens:simatic_hmi_comfort_panels_22%22_firmware cpe:/o:siemens:simatic_hmi_comfort_panels_4%22_firmware cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_firmware cpe:/o:siemens:simatic_pn%2fpn_coupler_firmware cpe:/o:siemens:simatic_s7-1200_cpu_1211c_firmware cpe:/o:siemens:simatic_s7-1200_cpu_1212c_firmware cpe:/o:siemens:simatic_s7-1200_cpu_1214c_firmware cpe:/o:siemens:simatic_s7-1200_cpu_firmware cpe:/o:siemens:simatic_s7-1500_cpu_firmware:1.5.1 cpe:/o:siemens:simatic_s7-1500_cpu_firmware:1.6 cpe:/o:siemens:simatic_s7-1500_cpu_firmware:1.8.2 cpe:/o:siemens:simatic_s7-300_cpu_312_ifm_firmware cpe:/o:siemens:simatic_s7-300_cpu_313_firmware cpe:/o:siemens:simatic_s7-300_cpu_314_ifm_firmware cpe:/o:siemens:simatic_s7-300_cpu_315-2_dp_firmware cpe:/o:siemens:simatic_s7-300_cpu_315_firmware cpe:/o:siemens:simatic_s7-300_cpu_316-2_dp_firmware cpe:/o:siemens:simatic_s7-300_cpu_318-2_firmware cpe:/o:siemens:simatic_s7-300_cpu_firmware cpe:/o:siemens:simatic_s7-400_dp_v7_firmware cpe:/o:siemens:simatic_s7-400_pn_v7_firmware cpe:/o:siemens:simatic_s7-400_v6_firmware cpe:/o:siemens:simatic_s7-410_v8_firmware cpe:/o:siemens:simatic_winac_rtx_%28f%29_2010_firmware:- cpe:/o:siemens:sinamics_dcm_firmware:1.5:- cpe:/o:siemens:sinamics_dcp_firmware cpe:/o:siemens:sinamics_g130_firmware cpe:/o:siemens:sinamics_g150_firmware cpe:/o:siemens:sinamics_gl150_firmware cpe:/o:siemens:sinamics_gm150_firmware cpe:/o:siemens:sinamics_s110_firmware cpe:/o:siemens:sinamics_s120_firmware cpe:/o:siemens:sinamics_s150_firmware cpe:/o:siemens:sinamics_sl150_firmware cpe:/o:siemens:sinamics_sm120_firmware:- CVE-2019-10936 2019-10-10T10:15:14.707-04:00 2019-10-15T17:45:35.270-04:00 5.0 NETWORK LOW NONE NONE NONE PARTIAL http://nvd.nist.gov 2019-10-11T10:57:20.290-04:00 CONFIRM https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), SIMATIC CFU PA (All versions < V1.2.0), SIMATIC ET 200AL (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM 155-5 PN BA (All versions < V4.2.3), SIMATIC ET 200MP IM 155-5 PN HF (All versions), SIMATIC ET 200MP IM 155-5 PN ST (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM 155-6 PN BA (All versions), SIMATIC ET 200SP IM 155-6 PN HA (All versions), SIMATIC ET 200SP IM 155-6 PN HF (All versions < V4.2.2), SIMATIC ET 200SP IM 155-6 PN HS (All versions), SIMATIC ET 200SP IM 155-6 PN ST (All versions), SIMATIC ET 200SP IM 155-6 PN/2 HF (All versions < V4.2.2), SIMATIC ET 200SP IM 155-6 PN/3 HF (All versions < V4.2.1), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels (All versions), SIMATIC PN/PN Coupler (All versions), SIMATIC PROFINET Driver (All versions < V2.1), SIMATIC S7-1200 CPU family (incl. F) (All versions), SIMATIC S7-1500 CPU family (incl. F) (All versions < V2.0), SIMATIC S7-300 CPU family (incl. F) (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC S7-400 V6 (incl F) and below (All versions), SIMATIC S7-400H V6 (All versions < V6.0.9), SIMATIC S7-410 V8 (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions), SINAMICS G110M V4.7 (PN Control Unit) (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 (PN Control Unit) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 (Control Unit) (All versions), SINAMICS G150 (Control Unit) (All versions), SINAMICS GH150 V4.7 (Control Unit) (All versions), SINAMICS GL150 V4.7 (Control Unit) (All versions), SINAMICS GM150 V4.7 (Control Unit) (All versions), SINAMICS S110 (Control Unit) (All versions), SINAMICS S120 V4.7 (Control Unit) (All versions), SINAMICS S150 (Control Unit) (All versions), SINAMICS SL150 V4.7 (Control Unit) (All versions), SINAMICS SM120 V4.7 (Control Unit) (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of specially crafted UDP packets are sent to device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.